Damper using shearing resistance of silicone oil. Limited angle usage.
"Quick start, slow end" motion control.
(Torque increases as the rotation angle changes.)
【 Characteristics 】
・Rotation direction : Left direction
・Torque : 1 type
Technical requirements:
1. Torque test conditions: 23 ± 2 ℃;
2. Static high and low temperature requirements: 0~70 ℃;
3. Durability requirements for dampers: Durability test speed 10r/min, 90 degrees forward/1.5s,
Pause for 1 second and then reverse for 90 degrees/1.5 seconds, forming one cycle with a durability of 10000 cycles;
4. The maximum rotation angle of the product axis is 111 °, and the buffering direction is in the left direction
・Specifications are subject to change without notice.